Wednesday 22 July 2015

How high should i install my carbon monoxide detector

Top sites by search query "how high should i install my carbon monoxide detector"

  http://www.greenbuildingadvisor.com/community/forum/general-questions/16884/where-best-place-put-carbon-monoxide-detector-home
Ronald, The gravity of air is 1 and the gravity of Carbon Monoxide is .9657 (per the EPA), which is almost identical; however since CO is usually mixed with warm air expelled by the appliances, it tends to rise with the warm air. Because CO has nearly the same specific gravity as air, the alarms can be located either low (for plug-in units) or high on ceilings or 6" below ceiling on walls (avoid corners where air is dead)

First Alert CO605 Plug-In Carbon Monoxide Alarm with Battery Backup - Walmart.com


  http://www.walmart.com/ip/First-Alert-Plug-In-With-Battery-Backup-Carbon-Monoxide-Detector/5639995
Except to the extent prohibited by applicable law, any implied warranty of merchantability or fitness for a particular purpose is limited in duration to the duration of the above warranty. I purchased one for each floor of the house including the basement Was this review helpful? Yes (10) No (3) Report Thank you! You have successfully submitted feedback for this review

Context Footer - Carbon Monoxide Facts


  http://www.firstalert.com/carbon-monoxide-facts
When appliances and vents work properly, and there is enough fresh air in your home to allow complete combustion, the trace amounts of CO produced are typically not dangerous. What do I do if my carbon monoxide alarm goes off? Never ignore an alarm! It is very possible that you won't be experiencing symptoms of CO poisoning when the alarm sounds

503 - Service Unavailable Error


  http://www.amazon.co.uk/Kidde-KID10LLDCO-Monoxide-Digital-Battery/dp/B00F351Q6O
503 - Service Unavailable Error We're sorry An error occurred when we tried to process your request.We're working on the problem and expect to resolve it shortly

  http://www.doh.wa.gov/CommunityandEnvironment/Contaminants/CarbonMonoxide
What are some common sources of carbon monoxide? Carbon monoxide is produced by incomplete combustion from cars and trucks, small gasoline power equipment like weed trimmers and chain saws, boat engines, gas and camp stoves, lanterns, burning charcoal and wood, and gas ranges, ovens, or furnaces. Contact Us Agency Contacts Locations and Directions General Information: Email 800-525-0127 TTY Users dial 711 Access Washington Contact our Web team Social Media Notices Privacy Notice Copyright Statement Publications Health Education Resource Exchange Publication List Alternate Format Requests For people with disabilities, Web documents in other formats are available on request

  http://www.firstalertstore.com/store/categories/carbon_monoxide_alarms_FAQ.htm
Different kinds of explosive gas can be detected and it is recommended that any home that utilizes natural or propane gas have at least one explosive gas leak detector. The diffusion of carbon monoxide in air is relatively even, meaning that a source of carbon monoxide can distribute the gas evenly throughout the room and house

  http://www.fireprotectiononline.co.uk/carbon-monoxide-alarms/
Figures suggest that there may be over 200,000 flues that have become hidden by renovations, building alterations etc, so it's worth checking if you have an older home or premises. The clear digital display constantly monitors CO levels, sounding the alarm well in advance of dangerous levels, and the unit has a back-up battery in case of power failure

hvac - Can I modify the vent from my high efficiency furnace to prevent possible damage to the exterior of my home? - Home Improvement Stack Exchange


  http://diy.stackexchange.com/questions/36975/can-i-modify-the-vent-from-my-high-efficiency-furnace-to-prevent-possible-damage
Local Building Code Manufacturer's installation manual Both of those will probably address how far away from a window or door and how far away from certain building materials the exhaust vent must be. Another issue i see is that any exhaust for a high efficiency gas appliance must be insulated when being run in an unconditioned space (such as in a garage or running under a deck)

Carbon Monoxide


  http://www.boiler-systems.co.uk/carbon-monoxide/
Less effective detectors work on the principle where a coloured mark on the detector paper changes colour over time when dangerous carbon monoxide gas is detected. If the flame changes from blue to yellow or orange this could mean that carbon monoxide is present and you should have the appliance inspected by a professional

Carbon monoxide poisoning


  http://www.netdoctor.co.uk/health_advice/facts/carbonmonoxide.htm
Acute exposure is easier to diagnose as the symptoms are more pronounced, but it is the more common chronic exposure symptoms that are more subtle and difficult to tell apart from other conditions. What to do if the alarm sounds It is essential to read the instruction manual accompanying the detector because it provides important information on where to place it, how to use it and what to do if the alarm goes off

NYC Department of Buildings - Carbon Monoxide Detectors FAQ


  http://www.nyc.gov/html/dob/html/codes_and_reference_materials/co_faq.shtml
Newly constructed and substantially improved buildings must have hard-wired detectors.Can I purchase one device that detects for both smoke and carbon monoxide?Yes, this is called a "combo-unit." Combo-units must be installed at or near the ceiling.HOW MANY AND WHERE SHOULD THE DETECTORS BE INSTALLED?How many carbon monoxide detectors must I install?This depends on the configuration of the house or apartment. This sort of system must provide an alarm in spaces identified in the Rules.Are schools, universities and libraries (G Occupancies) subject to the new law?Yes, but the required installation in each of these categories is different from what is required in homes

Which Is Heavier, Carbon Monoxide, Or Air? - Naked Science Forum


  http://www.thenakedscientists.com/forum/index.php?topic=13905.0
Information presented on this website is the opinion of the individual contributors and does not reflect the general views of the administrators, editors, moderators, sponsors, Cambridge University or the public at large

  http://www.city-data.com/forum/house/309784-where-install-smoke-carbon-monoxide-detectors.html
A CO detector on the ceiling does absolutely no good because dangerous levels could have been reached before the CO ever gets that high (fills up a room). In general more is better if they are maintained and actually working, I would prefer to spend more for fewer quality sensors than buy a lot of cheap ones for the same money

Kidde KN-COPF-i Silhouette Wire-in Low Profile Carbon Monoxide Alarm - Smoke Detectors - Amazon.com


  http://www.amazon.com/Kidde-KN-COPF-i-Silhouette-Profile-Monoxide/dp/B001LF2UDI
Now I wish I had installed it at the far end of the hallway just to reduce the light level.I did the test the CO detector and cross-test with a Silhouette smoke detector. I didn't like that I had to cut out three larger holes in my wall, pull out the old single boxes and replace them with doubles, still, it's not a lot of work to do so

ATSDR - Public Health Statement: Carbon Monoxide


  http://www.atsdr.cdc.gov/phs/phs.asp?id=1146&tid=253
Reduce outdoor exposure to carbon monoxide You can reduce your exposure to carbon monoxide outdoors by avoiding running or exercising near busy roadways. top 1.4 How can carbon monoxide enter and leave my body? Carbon monoxide enters and leaves the body Carbon monoxide in the air rapidly enters all parts of the body, including blood, brain, heart, and muscles when you breathe

  http://www.firstalertstore.com/store/catalog.asp?item=1236
Q: What is the proper way to do a carbon monoxide alarm test? A: The following procedure is the proper way to do a carbon monoxide alarm test - Press and hold the Test Button on the front of the alarm until the alarm sounds. Different kinds of explosive gas can be detected and it is recommended that any home that utilizes natural or propane gas have at least one explosive gas leak detector

  http://www.cpsc.gov/en/Safety-Education/Safety-Education-Centers/Carbon-Monoxide-Information-Center/Carbon-Monoxide-Questions-and-Answers-/
These products include malfunctioning fuel-burning appliances such as furnaces, ranges, water heaters and room heaters; engine-powered equipment such as portable generators; fireplaces; and charcoal that is burned in homes and other enclosed areas. If the source of the CO is determined to be a malfunctioning appliance, DO NOT operate that appliance until it has been properly serviced by trained personnel

  http://www.jaymarinspect.com/carbon-monoxide-detector.html
Where bedrooms are separated and the audibility of the alarm or detector to occupants within the bedroom area could be seriously impaired, more than one unit could be needed. Home Inspectors and Codes - 1 of 4 Home Inspectors and Codes - 2 of 4 Home Inspectors and Codes - 3 of 4 Home Inspectors and Codes - 4 of 4 Home Inspectors Are Just Placebos How Not To Install Kitchen Cabinets How To Choose A Home Inspector How To Pick A Lock ..

Resources - FAQ


  http://www.firstalert.com/resources/faq
How do you recommend to clean fire extinguisher residue after using a fire extinguisher? To clean fire extinguisher residue after using an extinguisher, sweep and vacuum up as much of the residue as possible. Different kinds of explosive gas can be detected and it is recommended that any home that utilizes natural or propane gas have at least one explosive gas leak detector

CDC - Carbon Monoxide Poisoning - Frequently Asked Questions


  http://www.cdc.gov/co/faqs.htm
Using a gas camp stove indoors can cause CO to build up inside your home, cabin, or camper.Never use a generator inside your home, basement, or garage or less than 20 feet from any window, door, or vent. Each year, more than 400 Americans die from unintentional CO poisoning not linked to fires, more than 20,000 visit the emergency room, and more than 4,000 are hospitalized

  http://www.diy.com/help-advice/how-to-install-test-and-maintain-smoke-and-carbon-monoxide-alarms/CC_npcart_3600003.art
They're easy to check; simply press the test button that is visible on the unit The unit will emit a loud alarm for approximately five seconds and then stop automatically There is an LED light that will also flash during the audible signal If your alarm does not sound or flash, this is a sign that the batteries need to be changed. Do not sleep in the room Call the Gas Emergency Freephone Number 0800 111 999 Visit your doctor or Accident and Emergency urgently and tell then you believe you have symptoms related to carbon monoxide

  http://www.ehow.com/video_7513622_install-carbon-monoxide-alarms.html
At a minimum, there should be one CO detector on each floor of every residential dwelling, near the living space or in the living space, and that can also be heard from the bedroom or sleeping areas within the dwelling. Again, the CO detector should be mounted at a minimum on each level or each floor of the residential dwelling, in or near the living spaces, and so it can be heard from the sleeping or bedroom areas

No comments: